Products
Abbott Diabetes Care is devoted to developing innovative products to better serve the needs of people living with diabetes through advanced technology and research.
![]() |
Monitoring glucose levels provides information about the effects of food
intake, medication, activity and stress as glucose levels change throughout the
day and night. Self-monitoring provides results that are used to determine if
an adjustment needs to be made to insulin, other diabetic medications, diet
and/or activity to achieve optimal diabetes self-management in consultation
with a health care professional. Learn about Abbott Diabetes Care products and
how they help reduce the discomfort and inconvenience of blood glucose
monitoring, by introducing systems that are easier to use, require less blood
and provide faster results
|
![]() |
Continuous glucose sensors offer the potential to significantly increase
the amount of clinically relevant information available to individuals with
diabetes. Such information could be used to help improve clinical decisions
made by the users and their healthcare provider.
|
![]() |
The OmniPod® Insulin Management System is the world's only tubing-free
insulin pump. OmniPod offers people living with insulin-requiring diabetes all
the benefits of insulin pump therapy. OmniPod has just two components: the
small, discreet, watertight Pod, worn almost anywhere on the body where one
would take an injection; and the PDM (Personal Diabetes Manager), a hand-held
device that communicates wirelessly to program the Pod, calculates suggested
doses and has a built-in FreeStyle® blood glucose meter.
|
![]() |
Abbott Diabetes Care data management system is intended for use as an accessory to FreeStyle® blood glucose monitoring systems and Precision® blood glucose monitoring systems to aid people with diabetes and health care professionals in the review, analysis, and evaluation of historical blood glucose test results. Learn more about our data management tool and how it provides important information to help promote a healthy lifestyle. Note: Data Cable Sold Separately. |
![]() |
If you're just getting started with insulin injections, or are thinking of
making a change in your injection device, you'll want to know all you can about
the numerous options from which to choose. Learn about the Abbott Diabetes Care
insulin syringe that is designed for maximum comfort and value.
|
![]() |
Wherever and whenever healthcare professionals need accurate results
immediately, Abbott Point-Of-Care systems are there. Learn how Abbott is
revolutionizing point-of-care testing.
|
CoPilot® System for the FreeStyle Navigator® System Intended Use and Application:
The CoPilot system is intended for use in home and clinical settings by patients and healthcare professionals. It is intended to aid people with diabetes and healthcare professionals in the review, analysis and evaluation of information such as historical blood glucose test results, insulin dosages, carbohydrate intake, and exercise data in support of an effective diabetes health management program. It can be used with supported Abbott Diabetes Care blood glucose monitoring systems, where data is uploaded, saved, analyzed, displayed as charts, graphs and reports, printed, and shared.
Users should be aware that the CoPilot system is merely an information management tool – it does not provide diagnostic information, nor does it give advice on the management of diabetes, and it is therefore not intended to substitute for the support of a healthcare professional. Home users should always consult their healthcare professional if they have any queries or concerns about diabetes management.
The CoPilot Health Management System for FreeStyle Navigator Continuous Glucose Monitoring System (CoPilot system for FreeStyle Navigator) allows data to be uploaded from the FreeStyle Navigator system to the CoPilot system, where it can be saved, analyzed, displayed as reports, charts and graphs, printed and shared.
Indications and Important Safety Information for the FreeStyle Navigator® System
Safety Information: Users should read all of the instructions in the User's Guide before using the FreeStyle Navigator® Continuous Glucose Monitoring System. Adjustments to treatment should be done under the guidance of the user's health care team.
Indications for Use: The FreeStyle Navigator Continuous Glucose Monitoring System is indicated for continually recording interstitial fluid glucose levels in people (ages 18 and older) with diabetes mellitus for the purpose of improving diabetes management. Readings and alarms about glucose levels from the FreeStyle Navigator Continuous Glucose Monitoring System are not intended to replace traditional blood glucose monitoring. Before adjusting therapy for diabetes management based on results and alarms from the FreeStyle Navigator Continuous Glucose Monitoring System, traditional blood glucose tests must be performed. The FreeStyle Navigator Continuous Glucose Monitoring System provides a built-in blood glucose meter to confirm the continuous glucose result.
The FreeStyle Navigator Continuous Glucose Monitoring System provides real-time readings, graphs, trends, and glucose alarms directly to the user. The FreeStyle Navigator Continuous Glucose Monitoring System is intended to be used in home settings to aid people with diabetes in predicting and detecting episodes of hypoglycemia and hyperglycemia and in clinical settings to aid health care professionals in evaluating glucose control. The FreeStyle Navigator Continuous Glucose Monitoring System is available only by prescription.
Contraindications: The FreeStyle Navigator Continuous Glucose Monitoring System must be removed prior to Magnetic Resonance Imaging (MRI).
Prescription Device: Federal law restricts the sale of this device by or on order of a physician.
Warnings/Precautions: Infection, inflammation, or bleeding at the glucose sensor insertion site are possible risks of inserting a sensor into your skin. If you believe your results are not reliable, or are inconsistent with how you feel, perform a blood glucose mode test to measure your glucose. If the problem continues, discard the old sensor and insert a new sensor. Performance of the system under conditions of fluctuating hydration levels such as during renal dialysis has not been evaluated. Unintended dislodging of the sensor due to excessive perspiration, exercise, or bumping, may cause unreliable or no results without warning. Performance of the FreeStyle Navigator system has not been evaluated in pregnant women.
DOC08795-Rev-H 07/09